G2T Programmers Guide Rev-A 17-Nov-2014
34
5.2. IEEE 488.2 Compliant Command Set
5.2.1. System Specific Commands - Tri-Stage
The architecture of Tri-Stage systems allow for specific commands
applicable to the following systems.
S2560E-xx-xxxxx
S2561E-xx-xxxxx
The operand range of the following commands must be from 1 to
the highest acceptable value for the system. The use of ANY or
ALL is not acceptable
5.2.1.1. EXClude command
This command is used to exclude a particular signal path.
EXClude [OUtput] output, [INput] input, [MIdstage] midstage
example:
EXClude from output 1, to input 1, midstage 1
5.2.1.2. INClude command
This command is used to undo a signal path exclusion.
INClude [OUtput] output, [INput] input, [MIdstage] midstage
example:
INClude from output 1, to input 1, midstage 1
5.2.1.3. XCL command
This command clears all signal path exclusions. The exclusion table
allows for 100 entries.
example:
XCL